In underground parking garages, the control of carbon monoxide (CO) concentrations has long relied on ventilation-based dilution. However, such ventilation systems suffer from inherent limitations, including high energy consumption, delayed response times, and inconsistent performance during peak periods. Catalytic oxidation technology offers an alternative approach: converting CO into CO₂ at ambient temperatures, serving as a supplementary purification method to the ventilation system. An effective division of labor involves using ventilation to ensure baseline air exchange and heat removal, while employing catalytic purification to rapidly reduce CO concentration peaks. This synergistic strategy has been validated in demonstration projects within semi-enclosed spaces, achieving an average CO purification efficiency of 82.1%. This article systematically examines the synergistic logic between catalytic purification and ventilation systems in underground parking garages, covering technical principles, integration strategies, and key design considerations.
I. Physical Limits of Ventilation-Based Dilution and the Rationale for Catalytic Oxidation
1.1 Regulatory Requirements and Energy Constraints for Ventilation Systems
Current standards for CO concentration control in underground parking garages are governed by GB 50067-2011, which mandates that CO concentrations remain at or below 30 mg/m³ during normal operation and no higher than 100 mg/m³ during peak periods, with a minimum air exchange rate of 6 air changes per hour (ACH). For an underground parking garage with an area of 2,000 m² and a ceiling height of 3 m, an air exchange rate of 6 ACH requires an exhaust capacity exceeding 36,000 m³/h. Maintaining such an airflow volume results in significant annual energy consumption by the ventilation fans.
A more critical challenge lies in the time-varying nature of CO concentrations. CO emissions from vehicles during cold starts and idling are substantially higher than those during normal operation. As semi-enclosed environments, underground parking garages often feature poor airflow, making them prone to the localized accumulation of pollutants—particularly near ramp entrances and areas with high vehicle density. CO concentrations tend to surge during morning and evening peak hours, only to drop significantly during off-peak periods. Relying solely on maximum-capacity ventilation leads to excessive energy use for much of the time, while relying exclusively on CO sensor-based start-stop controls risks a delayed response during peak periods. 1.2 Complementary Logic of Catalytic Oxidation Technology for Ventilation Strategies
Catalytic oxidation does not alter the physical distribution of CO; instead, it converts CO into CO₂ through a chemical reaction: 2CO + O₂ → 2CO₂. By providing active sites, the catalyst lowers the activation energy of the reaction, enabling it to proceed efficiently at low temperatures—ranging from ambient temperature up to 150°C. Consequently, integrating catalytic purification with ventilation-based dilution allows for lower CO concentrations at a constant airflow rate, or, conversely, enables a reduction in ventilation volume—and thus energy consumption—while still meeting target CO concentration levels. The value of catalytic oxidation lies in its ability to serve as a "peak-shaving" mechanism; it can be activated or deactivated rapidly and functions at ambient temperatures, eliminating the need for ventilation systems to operate at full capacity at all times.
II. Types and Technical Characteristics of CO Catalysts for Garage Environments
2.1 Manganese-Based Composite Oxide Catalysts
Manganese-based catalysts utilize manganese dioxide and copper oxide as their core active components, facilitating the catalytic oxidation of CO through the redox cycles of transition metal oxides. The reaction mechanism primarily follows the Mars-van Krevelen model: lattice oxygen on the catalyst surface is consumed during the CO oxidation process and subsequently replenished by oxygen from the gas phase, thereby completing the redox cycle.
Recent research indicates that doping with copper can effectively modulate the catalytic performance of manganese oxides. The incorporation of Cu increases the specific surface area and pore volume, weakens Mn-O bonds, raises the proportion of low-coordination oxygen vacancies, and elevates the average oxidation state of manganese—all of which significantly enhance CO catalytic oxidation activity. Among doped ε-MnO₂ catalyst systems, those doped with Cu exhibit the fastest reaction rates and the lowest temperatures for complete conversion. Density Functional Theory (DFT) calculations confirm that Cu doping is more effective than doping with Co, Ni, or Fe at inducing oxygen vacancy defects.
Manganese-based systems are capable of achieving highly efficient CO conversion at ambient temperatures. Research indicates that the Cu0.1/N60-MnO₂ catalyst achieves a CO conversion rate of nearly 100% at 25°C and maintains over 90% of its activity for 40 hours. This catalyst also exhibits high CO oxidation activity under oxygen-free conditions—a feature of practical significance for localized areas within underground parking garages where oxygen concentrations may be low.
2.2 Noble Metal Catalysts
Noble metal catalysts utilize elements such as Pd or Pt as active components, supported on honeycomb-structured cordierite ceramics or metallic substrates. These catalysts offer superior low-temperature activity, with light-off temperatures as low as 80–120°C; however, their initial capital cost is significantly higher than that of non-noble metal systems. For underground parking garage environments, where CO concentrations typically do not exceed 100 ppm, manganese-based systems—if designed appropriately—can meet the required standards. Noble metal systems are more advantageous in scenarios characterized by greater fluctuations in CO concentration or requirements for faster response times.
2.3 Specific Catalyst Requirements for Parking Garage Environments
The environment of an underground parking garage imposes several key performance requirements on CO catalysts. The ability to initiate catalytic activity at ambient temperature is paramount; as garage temperatures generally range from 0°C to 40°C, the catalyst must remain effectively active within this span. Adaptability to space velocity is equally critical: given the high space velocities typical of garage ventilation systems, research has shown that monolithic catalysts designed for such settings can effectively eliminate low-concentration CO at space velocities as high as 60,000 h⁻¹. Moisture resistance is also a vital consideration; water molecules can compete with CO for active sites and may form surface species—such as carboxylates and bicarbonates—that diminish catalytic activity. Furthermore, airborne particulate matter entering the catalytic module can cover the active sites on the catalyst surface; consequently, incorporating a pre-filtration device upstream of the catalytic module is an essential design requirement. III. Three Integration Approaches for Catalysts and Ventilation Systems
3.1 Series Configuration: Catalytic Modules Embedded in Air Ducts
Integrated catalytic modules are installed within the garage’s exhaust or return air ducts, where CO-containing air undergoes catalytic oxidation as it passes through. This approach requires minimal structural modification, making it well-suited for upgrading CO mitigation in existing garages. It should be noted that these modules increase airflow resistance; therefore, this pressure drop must be factored into the total resistance calculation for the ventilation system. Modules should be positioned in duct sections where CO concentrations are relatively stable and dust levels are low to prevent particulate matter from clogging the catalyst pores.
3.2 Parallel Configuration: Independent Recirculating Purification Units
Standalone air purification units are deployed within the garage to draw in ambient air, purify it via catalysis, and return it to the space. These units operate in parallel with the main ventilation ductwork without altering the existing ventilation system’s structure. This flexible deployment allows for targeted placement based on the spatial distribution of CO concentrations—ideal for areas with higher local concentrations, such as near ramp entrances or dense parking zones, as well as "dead zones" not adequately covered by the primary ventilation system.
3.3 Integrated Configuration: Coordinated Control of Catalysis and Intelligent Ventilation
A network of CO concentration sensors is linked to both the catalytic purification units and the ventilation fans. When CO levels fall below a first threshold, only the catalytic purification units operate; if concentrations exceed a second threshold, both the catalytic units and the ventilation system are activated. The core logic of this tiered response strategy is to use catalytic purification for "routine" CO concentrations, while employing mechanical ventilation to handle "peak" conditions—thereby reducing the average power consumption of the ventilation fans.
In a demonstration project at an underground garage in a Jinan hospital, an integrated system—comprising dust removal, ambient-temperature catalytic oxidation of CO, and adsorption of NOx/HC—was tested over a three-month period with an airflow rate of 20,000 m³/h. The system achieved an average CO purification efficiency of 82.1%. This project is significant as it validates the feasibility and stability of catalytic oxidation technology under real-world underground parking conditions, extending its application beyond controlled laboratory environments. IV. Key Technical Considerations in Engineering Design
The placement of CO monitoring points directly affects the accuracy of linked control systems. In accordance with relevant standards, at least one CO monitoring point should be installed for every 1,000 m² within each smoke-control zone. It is recommended to position these sensors at a height of 0.8 to 1.2 meters—aligning with the human breathing zone—to provide a more accurate reflection of actual exposure levels. To ensure the spatial representativeness of the concentration data, the sampling interval between monitoring points should not exceed 15 meters.
The airflow resistance and replacement cycle of catalytic modules must be factored into the design phase. For monolithic honeycomb ceramic catalytic modules, the initial airflow resistance typically ranges from 200 to 500 Pa; this pressure drop must be included in the total resistance calculation for the ventilation system. The service life of a catalyst depends on specific operating conditions: in a garage environment with minimal dust and no sulfide interference, a manganese-based catalyst typically has an expected service life of 1 to 2 years. Once a catalyst becomes deactivated, its activity can be partially restored through methods such as air purging or thermal treatment, though the efficiency of this regeneration depends on the cause and extent of the deactivation.
The importance of pre-filtration is frequently underestimated. If particulate matter present in the air of an underground parking garage enters the catalytic module directly, it will coat the active sites, leading to a rapid decline in catalytic activity. Consequently, appropriate filtration equipment should be installed upstream of the catalytic module, with the replacement or cleaning cycle for these filters determined based on the actual dust load.
V. Conclusion
The core challenge in managing CO levels in underground parking garages lies in the mismatch between "dynamic demand" and "fixed supply": CO concentrations fluctuate with traffic flow, while adjusting the airflow of a ventilation system entails both response delays and energy costs. Catalytic oxidation technology offers a complementary solution by facilitating the conversion of CO at ambient temperatures. The value of a catalyst does not lie in replacing ventilation, but rather in enabling a shift from "continuous full-load operation" to "on-demand intervention." A well-balanced division of labor—using ventilation as a baseline safeguard and catalytic oxidation to manage peak concentrations—provides a viable approach that ensures both safety compliance and operational cost-efficiency. As manganese-based catalysts continue to be optimized for low-temperature activity and resistance to moisture and sulfur, the scope of this synergistic strategy is expanding from large commercial garages to a wider range of applications.